Hotline

13661219353

Current location:Home  >  Product Center  >centrifuge > High Speed Centrifuge > JW-2017H High-speed Centrifuge

JW-2017H High-speed Centrifuge

Describe:Gradient PCR instrument high-speed centrifuge 1. Speed: 17000rpm; Large relative centrifugal force: 21970× g; Speed accuracy: ± 20rpm

  • Model No.:JW-2017H
  • country of origin:China
  • Warranty period:1 Year
  • After sales service:Online Support
  • Update time:2025-11-11
  • Visits:372
Product consulting Data download

Detailed introduction

Large screen true color LCD, full touch screen operation interface;  Microcomputer control, no carbon brush AC frequency conversion motor drive, high speed accuracy, low noise;  Programmable operation, a variety of speed choice;  Centrifugal force and speed can be independently set and displayed on the same screen;  Unique DCT[Differential Centrifugation Technology] "differential centrifugation application technology.  Widely used in: teaching, scientific research, biochemical products, medical inspection, food safety, agricultural product testing, animal husbandry and aquatic testing, microbiology, molecular chemistry, environmental quality inspection and other industries.  

 Overall characteristics  

 ◆ Microcomputer control, large screen true color LCD display, full touch screen operation interface;  Directly set the working program, centrifugal force, speed, centrifugal time, temperature, lifting speed and the rotor type LCD display  

 ◆ No carbon brush AC frequency conversion motor drive, using a special drive module to ensure the reliability of the circuit  

 ◆ Double door lock system, automatically lock the door after starting, to ensure safe operation  

 ◆20 kinds of work program selection, users can freely program, call its set working parameters, easy to use, improve work efficiency  

 ◆15 kinds of acceleration /15 kinds of deceleration options, users can arbitrarily set one group of speed up and down according to sample requirements  

 ◆ With fixed speed timing (at set rpm), start timing two functions, the point is instantaneous high center (shotspin) function  

 ◆ Differential centrifugation: Reserve 5 differential centrifugation procedures, users can set according to demand  

 ◆ Double steel structure, stainless steel centrifugal chamber, to avoid corrosive substances  

 ◆ Automatic balance, unbalanced protection;  Error or imbalance alarm signal prompt, and automatic stop  

 ◆ Parameters can be arbitrarily changed during operation without stopping  

 ◆ Fastest speed up and down time <15s[H0512]  

 ◆SOFT has soft brake function, which can effectively prevent sample resuspension and protect sensitive samples;  Multistage damping damping design to ensure the centrifugal effect of the sample  

 ◆ Countdown function: countdown in seconds, real-time display of remaining working time  

 ◆ The centrifugal chamber has a condensate drainage hole to prevent water in the chamber  

 ◆ "Standby Cooling" pre-cooling function: in the standby state, it can be pre-cooled to the set temperature continuously  

 ◆ Standby function: When the compressor is reduced to the set temperature, it will automatically standby, reduce energy consumption, and extend the life of the compressor  

 ◆ "Fast Cool/Quick Lock" fast cooling function, from room temperature 21°C to biological zero 4°C ≤5 minutes  

 ◆ Rotor can be autoclaved at 121℃ for more than 2 hours, air tight Angle rotor, high biosafety  

 ◆ Automatic identification of magnetic rotor, no manual setting of rotor model (2012HR needs to be set in the interface), overspeed protection  

 ◆ Imported compressor, no fluorine refrigeration  

 ◆ Customized 485 communication interface, remote control [optional] 

  main technical parameters:

Model

JW-2012H

JW-2017H

JW-2018H

JW-2019H

Max Speed(rpm)

15500rpm

17500rpm

18800rpm

20000rpm

Max. Rcf(xg)

23449xg

23282xg

26870xg

30410xg

Capacity

5mlx12

10mlx12

10mlx12

50mlx6

Speed accuracy(rpm)

±10rpm

Timer range

1s~99h59min59s / Inching (Instantaneous) Centrifugation

Test Solution Heating

After operating for 20 minutes, the temperature rise of the test solution is < 10

Noise

50dB

58dB

58dB

58dB

Power supply

AC220V 50Hz 10A

AC220V 50Hz 10A

AC220V 50Hz 10A

AC220V 50Hz 10A

Power

280W

400W

400W

600W

Weight

22Kg

28Kg

28Kg

30Kg

Overall dimensions

 [L x W x H]

325x275x265mm

426x322x340mm

426x322x340mm

485x370x400mm

 Rotor configuration:

Model

JW-2012H

JW-2017H

JW-2018H

JW-2019H

Rotor

capacity

Max rpm/RCF

H0.136

capillary  

75mmx36 pieces long

Max Speed

/

12000rpm

12000rpm

12000rpm

Max RCF

16904xg

16904xg

16904xg

H0.232

0.2mlx4x8row

Max Speed

13000rpm

13000rpm

13500rpm

13500rpm

Max RCF

13037xg

13037xg

14059xg

14059xg

H0.264

0.2mlx8x8row

Max Speed

/

/

13000rpm

13000rpm

Max RCF

14926xg

14926xg

H0.512

0.5mlx12

Max Speed

15500rpm

17500rpm

18800rpm

20000rpm

Max RCF

18265xg

16435xg

18967xg

21466xg

H0.524

0.5mlx24

Max Speed

/

17500rpm

18800rpm

19500rpm

Max RCF

23282xg

26870xg

28908xg

H0.548

0.5mlx48

Max Speed

/

12500rpm

13000rpm

15000rpm

Max RCF

13626xg

14737xg

19621xg

H0212

1.5/2.2mlx12

Max Speed

/

17500rpm

18800rpm

20000rpm

Max RCF

23282xg

26870xg

30410xg

H0224

1.5/2.2mlx24

Max Speed

15500rpm

15500rpm

15800rpm

17500rpm

Max RCF

23449xg

23449xg

24365xg

29890xg

H0236

1.5/2.2mlx36

Max Speed

/

/

/

15000rpm

Max RCF

22388xg

H0312

3mlx12

Max Speed

/

/

8000rpm

8000rpm

Max RCF

4866xg

4866xg

H0512

5mlx12

Max Speed

15000rpm

15500rpm

16000rpm

16500rpm

Max RCF

17105xg

18265xg

19462xg

20698xg

H0612

5mlx12[Cryovial]

Max Speed

/

/

13000rpm

13000rpm

Max RCF

16155xg

16155xg

H0712

5mIx12

Max Speed

/

/

8000rpm

8000rpm

Max RCF

7119xg

7119xg

H1012

10mlx12

Max Speed

/

12800rpm

13500rpm

14000rpm

Max RCF

15863xg

17645xg

18976xg

H1508

15mlx8

Max Speed

/

/

/

12500rpm

Max RCF

16246xg

H3006

30mlx6

Max Speed

/

/

/

14000rpm

Max RCF

19722xg

H5006

50mlx6

Max Speed

/

/

/

12000rpm

Max RCF

15987xg

Note: The angle rotor equipped with the 2012H has a conical bottom without magnetic columns, and cannot be automatically identified. The rotor model must be directly set on the interface during centrifugation.

Product consulting

Message box

  • Product:

  • Message content:

  • Your unit:

  • Your name:

  • Contact number:

  • Common mailbox:

  • Detailed address:

  • Verification Code: