Product Desicription:

•ChemWell Fusion is an open system adaptable to ELISA and glow-type CLIA applications.
•ChemWell Fusion provides pre-dilution options, mixing, variable incubation, plate washing,total pipetting functions, the software times the addition of conjugates, substrates and 
stop solutions while monitoring sample and reagent volumes as well as other parameters to assure precise, reliable results.
•ChemWell Fusion is a fully automated immunoassay processor with a unique optical system that automatically reads both colorimetric and chemiluminescent assays.
•The instrument holds a 96 microwell plate or up to twelve 8-well strips.
•Each row in a microwell plate can run a different test even if the incubation times, wash 
cycles, and read modes are different. Smart software avoids timing conflicts.
•Assay applications can be programmed to create and store password protected menu of 
test protocols.
•Ease of operation through intuitive design
•Integrated precision pipetting & microwell plate washing
•The ability to run both ELISA & CLIA on the same microwell strip plate
• Intelligent software that prevents timing conflicts
• Complete patient database with search and history tracking system
• Flexible reporting options including export to excel or LIS
• Customizable reagent and sample placement offering flexibility
• An open system, with the ability to program any assay Lockout security protection options

• Simplified maintenance


Three easy steps to reliable results

Enter or download patient data, request test with calibration and QC options.
Load samples and reagents.
ChemWell automatically processes the workload, monitoring
reagent and sample supply, and presents results for review, printing and storage.


• Accurate results, dependable performance
• Automated analyzer for microwell based ELISA or CLIA
• Versatile open system

• Cost-effective operation

  

  Technical parameter:

Min. and Max. volume

2 µL - 1.95 mL

Precision for volumes <5 µL

<2.5% CV

Precision for volume >5 µL

<1% CV

Maximum number of specimens

96 (including calibrators and controls

Maximum number of reagents

Typically 27 or 44

Standard reagent rack

27 positions, other configurations optional

Reaction vessel

Standard 96 well microwell plates or strips

Instrument bottles

 

1 L Priming bottle

2 L wash

1 L rinse (or second wash)

2 L waste bottle

Thermal control

 

Plate/Well 25 °C, 37 °C, or ambient temperature

Temperature controlled to 25 °C providing the ambient room temperature is

below 25 °C

Wash head

Programs

 

8-probe, automatic prime and rinse

Programs Wash protocols are user programmable for aspirate, dispense, soak, mix

Reading

Glow luminescence & absorbance

Light Source

Halogen Lamp

Spectral range

340-700nm

ELISA absorbance

405, 450, 492, and 630 nm

Photometric accuracy

± (1% of the reading +0.005A from 0 to 1.5A)

± (2% of the reading from 1.5 to 3.0A)

Software format

CD-ROM and Internet upgrades

Supported operating systems

Windows® 7, 8 and 10

Minimum system requirements

Operating System dependent* please see Windows® system requirements

Calculation modes

Absorbance, single standard, factor, multi-calibrator point-to-point, linear

regressions, log-logit, cubic spline, and nonlinear regressions (curve fit), RLU

LIS integration

LIS compatible, patient database stores test results

Dimensions & weight

66 cm W. x 51 cm L. x 40 cm H. Approx. weight = 35 kg

34” W. x 20” L. x 16” H. Approx. weight = 77 lbs